Single and double wall stainless, PPS, concentric, flexible, CLV and cascade for gas, oil, pellets, wood and coal. Order online from Ventichim in Zandhoven, Belgium.
Read more
Which flue system do you need?
That depends on the appliance and on where the flue runs.
- Gas or oil condensing boiler: PPS up to 120 °C or stainless steel. We advise against an aluminium flue pipe: condensate with a pH of 2 to 5 attacks it.
- Wood or coal: IE single wall stainless or ID double wall stainless.
- Pellet stove: IP black stainless or Pellet Design.
- Lining an existing chimney: flexible.
- Room-sealed boiler with a concentric connection: concentric.
- Several boilers: CLV per dwelling, cascade in one boiler room, collective renovation in an existing shaft.
New boiler, old flue?
A flue lasts about 15 years, as long as the boiler. With a new boiler, the rule at most manufacturers is: new flue.