Base plate with condensate drain
Stainless steel base plate with condensate drain: the closing component at the foot of a vertical flue gas system. It seals the bottom of the column gas-tight and drains condensate in a controlled way through an integrated drain cap. Single wall construction in stainless steel 316, for single wall flue systems of the IE series. Available in Ø130, Ø150, Ø160, Ø180, Ø200 and Ø250. Select your flue diameter below.
Features
| Colour | Matt stainless steel |
| Diameter | 130, 150, 160, 170, 180, 200, 250 |
| Gasket | EPDM elastomer to UNI EN 14241-1, double lip (suitable for oil and gas) |
| Material | Stainless steel 316L |
| Suitable for | Gas, gas condensing, oil, oil condensing, pellets, wood, coal |
| Wall thickness | 0,5 mm, 0,6 mm |
| Test pressure | 5000 Pa |
| Temperature resistant | Overpressure 200 °C / Negative pressure 600 °C |
| Stock | In stock |
| Delivery time | Ordered before 3pm, delivered next day |
What is a base plate with condensate drain for?
In a vertically built flue gas system, inside a shaft or along a facade, the bottom of the column must be closed gas-tight and the condensate must be able to drain away. The base plate does both: it forms the closing foot of the flue and collects the condensate, which runs through the drain cap to a siphon or neutralisation box.
Technical data
| Material | stainless steel 316 |
| Construction | single wall |
| Diameters | Ø130 · Ø150 · Ø160 · Ø180 · Ø200 · Ø250 |
| Series | single wall stainless steel, IE series |
| Application | vertical flue gas exhaust, condensing and non-condensing appliances |
| Stock | in stock |
| Delivery time | ordered before 3 pm, delivered next day |
Frequently asked questions
Which diameter do I need?
The diameter of the base plate equals the internal diameter of the flue. If in doubt, check the appliance data plate or the EN 13384 calculation for the system.
Where does the condensate go?
Connect a hose from the drain cap to a siphon. For condensing gas or oil appliances a neutralisation box is often required; check local regulations (NBN B 61-002, NBN D 51-003).
Does the base plate carry the weight of the column?
It closes the flue and supports the lowest element. For taller columns, add a support bracket or console according to the installation instructions.
Is this the same as a tee with condensate drain?
No. A tee with a drain is used where the appliance connects to the flue; the base plate closes a column with no lateral connection.
Does it fit existing single wall stainless steel elements?
Yes, it connects to single wall stainless steel pipes and fittings of the same nominal diameter.